TM 9-2350-261-20-1 NO DATA OUTPUT FROM DATA PANEL A13 (M1068 ONLY) — Continued 0092 00 Y 1. Remove cable W126 plug P108 (1) from patch panel box A10 jack J139 (2). 2. Measure resistance between pin A on plug P108 (1) and socket A on plug P1 (3) of cable W126. Repeat for pins B through a. 3. Does multimeter read 0 ohms for each measurement? YN 1. Replace cable W126 (WP 0758 00). 2. Verify no faults found. 2Y 1. Replace patch panel box A10 (WP 0724 00). 2. Verify no faults found. 0092 00-2