TM-9-2350-261-20-1 Unit Maintenance Manual Volume 1 M113A2 M577A2 M1064 M1068 M1059 M901A1 Download
Page 507 of 1236
TM 9-2350-261-20-1 NO DC OUTPUT FROM DC POWER SUPPLY (M1068 ONLY) — Continued 0088 00 3Y 1. Measure resistance between circuit 10B terminals (1) on power supply PS2 (2) and power supply PS1 (3). 2. Measure resistance between circuit 8C terminals (4) on power supply PS2 (2) and power supply PS1 (3). 3. Measure resistance between circuit 3Z terminals (5) on power supply PS2 (2) and power supply PS1 (3). 4. Does multimeter read 0 ohms for each measurement? 3YN 1. Faulty lead 10B, 8C, and 3Z in power control enclosure. 2. Notify your supervisor. 4Y 1. Faulty power supply. 2. Notify your supervisor. 0088 00-5/6 blank