TM-9-2350-261-20-1 Unit Maintenance Manual Volume 1 M113A2 M577A2 M1064 M1068 M1059 M901A1 Download

Page 501 of 1236

TM 9-2350-261-20-1 NO POWER TO AC CIRCUITS (M1068 ONLY) — Continued 0087 00 10Y 1. Set BLACKOUT ENABLE SWITCH to down position. 2. Set AC LIGHTS SWITCH in upward position. See TM 11-7010-256-12&P. 3. Measure resistance between terminal 2 (1) and terminal 1 (2) of circuit breaker CB17 (3). 4. Does multimeter read 0 ohms? 10YN 1. Replace circuit breaker CB17 (WP 0730 00). 2. Verify no faults found. 0087 00-11