TM-9-2350-261-20-1 Unit Maintenance Manual Volume 1 M113A2 M577A2 M1064 M1068 M1059 M901A1 Download
Page 495 of 1236
TM 9-2350-261-20-1 NO POWER TO AC CIRCUITS (M1068 ONLY) — Continued 0087 00 3Y 1. Remove plug P11 (1) from J31 (2). 2. Measure resistance of circuit 18H between power enclosure jack J31 (2) socket B and terminal block E3 (3). 3. Measure resistance for circuit 18E between jack J31 (2) socket D and terminal block E3 (3). 4. Does multimeter read 0 ohms for both readings? 3YN 1. Faulty lead 18E and/or lead 18H. 2. Notify your supervisor. 0087 00-5