TM-9-2350-261-20-1 Unit Maintenance Manual Volume 1 M113A2 M577A2 M1064 M1068 M1059 M901A1 Download

Page 487 of 1236

TM 9-2350-261-20-1 NO POWER TO DC CIRCUITS (M1068 ONLY) — Continued 0086 00 Y 1. Measure voltage between circuit breaker CB15 (1) terminal 1 at DC bus bar and power supply PS1 output negative terminal (2). 2. Does multimeter read 22 volts DC or more? YN 1. Go to Vehicle Batteries Discharge with External AC Power Applied (WP 0083 00). 0086 00-3