TM 9-2350-261-20-1 VEHICLE WILL NOT ACCEPT EXTERNAL AC POWER (M1068 ONLY) — Continued 0084 00 4Y 1. Remove cable W3 plug P1 (1) from jack J1 (2) on power distribution box (3) and plug P3 (4) from jack J24 (5) on power control enclosure (6). 2. Measure resistance between plug P1 (1) and plug P3 (4) as follows: P1 pin A to P3 socket A P1 pin B to P3 socket B P1 pin C to P3 socket C 3. Does multimeter read 0 ohms for each reading? 4YN 1. Replace cable W3 (WP 0739 00). 2. Verify no faults found. 5Y 1. Faulty power control enclosure. Beyond unit maintenance repair 2. Notify your supervisor. 0084 00-4