TM-9-2350-261-20-1 Unit Maintenance Manual Volume 1 M113A2 M577A2 M1064 M1068 M1059 M901A1 Download

Page 470 of 1236

TM 9-2350-261-20-1 VEHICLE WILL NOT ACCEPT EXTERNAL AC POWER (M1068 ONLY) — Continued 0084 00 2Y 1. Apply external source of AC power to SICPS vehicle. See TM 11-7010-256-12&P. 2. Remove cable W1 leads (1) from generator, if applicable. 3. Remove cable W2 plug J1 (2) from power entry box (3). 4. Measure resistance between W1 leads (1) and W2 plug J1 (2) as follows: W1 HOT to J1 pin A W1 NEU to J1 pin N W1 GND1 to J1 pin G1 W1 GND2 to J1 pin G2 5. Does multimeter read 0 ohms for all readings? 2YN 1. Replace cable W1/2. See TM 11-7010-256-12&P. 2. Verify no faults found. 0084 00-2