TM-9-2350-261-20-1 Unit Maintenance Manual Volume 1 M113A2 M577A2 M1064 M1068 M1059 M901A1 Download

Page 464 of 1236

TM 9-2350-261-20-1 VEHICLE BATTERIES DISCHARGE WITH EXTERNAL AC POWER APPLIED (M1068 ONLY) — Continued 0083 00 6Y 1. Turn OFF AC/DC power. 2. Remove 12 screws (1), lockwashers (2), and cover (3) from power control enclosure (4). Discard lockwashers. 3. Measure resistance between terminal 2 (5) of circuit breaker CB5 (6) and AC HIGH terminal (7) of power supply PS2 (8). 4. Does multimeter read 0 ohms? 6YN 1. Faulty circuit 10A. 2. Notify your supervisor. 0083 00-6