TM-9-2350-261-20-1 Unit Maintenance Manual Volume 1 M113A2 M577A2 M1064 M1068 M1059 M901A1 Download
Page 457 of 1236
TM 9-2350-261-20-1 FLUORESCENT LIGHTS DO NOT OPERATE (M1068 ONLY) — Continued 0082 00 3Y 1. Set power control enclosure AC MAIN switch to OFF. See TM 11-7010-256-12&P. 2. Remove cable W11 plug P2 (1) from light assembly plug P1 (2). 3. Measure resistance between sockets of P2 (1) and pins of plug P17 (3) on cable W11 (4) as follows: P2 socket H to P17 pin A P2 socket N to P17 pin B P2 socket G to P17 pin C 4. Does multimeter read 0 ohms for each measurement? 3YN 1. Replace cable W11 (WP 0747 00). 2. Verify no faults found. 4Y 1. Replace/repair light set assembly. See TM 10-5410-229-13&P. 0082 00-3/4 blank