TM-9-2350-261-20-1 Unit Maintenance Manual Volume 1 M113A2 M577A2 M1064 M1068 M1059 M901A1 Download

Page 452 of 1236

TM 9-2350-261-20-1 IN BLACKOUT MODE, FLUORESCENT LIGHTS OPERATE INCORRECTLY (M1068 ONLY) — Continued 0081 00 B6Y 1. Install cable W35 plug P1 (1) on adapter plug P2 (2). 2. Install W35 plug P9 (3) on jack 29 (4) of power control enclosure. 3. Measure resistance between relay XK5 (5) pin X2 (6), and relay XK3 (7) pin X2 (8). 4. Does multimeter read 0 ohms? B6YN 1. Faulty lead 3F of XK2. 2. Notify your supervisor. 0081 00-6