TM 9-2350-261-20-1 NO AC/DC INPUT TO ATCCS UPS POWER BOX (M1068 ONLY) — Continued 0080 00 T 1. Remove cable W43 plug P2 (1) from roadside AC power extension box A6 jack J6 (2). 2. Apply AC power to SICPS system. See TM 11-7010-256-12&P. 3. Set AC LEFT OUTLETS switches on power control enclosure panel to ON. 4. Measure voltage between sockets H and N of J6 (2). 5. Does multimeter read 110 volts AC or more? TN 1. Go to No Power From Roadside AC Power Extension Box A6 (WP 0074 00). 0080 00-2