TM-9-2350-261-20-1 Unit Maintenance Manual Volume 1 M113A2 M577A2 M1064 M1068 M1059 M901A1 Download

Page 426 of 1236

TM 9-2350-261-20-1 NO POWER FROM DC POWER EXTENSION BOX A9 (ALL EXCEPT JACK J23) — Continued 0076 00 T 1. Remove cable W10 plug P14 (1) from power control enclosure jack J34 (2). 2. Turn MASTER SWITCH to ON (see your -10). 3. Set DC LEFT OUTLETS switches (3) on power control enclosure panel to ON. See TM 11-7010-256-12&P. 4. Measure voltage between sockets A and B of jack J34 (2). Repeat measurement for sockets C and D. 5. Does multimeter read 22 volts DC or more for each measurement? TN GO TO BY (PAGE 0076 00-4) 0076 00-2