TM 9-2350-261-20-1 NO POWER FROM CURBSIDE AC POWER EXTENSION BOX A7 — Continued 0075 00 Y 1. Set AC RIGHT OUTLETS switches (1) to OFF and remove ALL power from SICPS system (see your -10 and TM 11-7010-256-12&P). 2. Remove cable W8 plug P1 (2) from curbside AC power extension box jack J1 (3). 3. Measure resistance between pins of plugs P1 (2) and P11 (4) on cable W8 as follows: P1 pin A to P11 pin A P1 pin B to P11 pin B P1 pin C to P11 pin C P1 pin D to P11 pin D P1 pin E to P11 pin E 4. Does multimeter read 0 ohms for each set of pins? YN 1. Replace cable W8 (WP 0744 00). 2. Verify no faults found. 2Y 1. Replace curbside AC power extension box A7 (WP 0719 00). 2. Verify no faults found. 0075 00-3