TM 9-2350-261-20-1 NO POWER FROM CURBSIDE AC POWER EXTENSION BOX A7 — Continued 0075 00 T 1. Remove cable W8 plug P11 (1) from power control enclosure jack J31 (2) 2. With AC power accepted, set AC RIGHT OUTLETS switches (3) on power control enclosure panel to ON. See TM 11-7010-256-12&P. 3. Measure voltage between sockets A and B of jack J31 (2). 4. Measure voltage between sockets C and D of jack J31 (2). 5. Does multimeter read 110 volts AC or more for both measurements? TN GO TO BY (PAGE 0075 00-4) 0075 00-2