TM-9-2350-261-20-1 Unit Maintenance Manual Volume 1 M113A2 M577A2 M1064 M1068 M1059 M901A1 Download
Page 416 of 1236
TM 9-2350-261-20-1 NO DC POWER FROM TENT INTERFACE PANEL A5 — Continued 0073 00 BY 1. Turn MASTER SWITCH to OFF (see your -10). 2. Remove ten screws (1) and lockwashers (2) and lower the faceplate (3). Discard lockwashers. 3. Set DC TENT INTERFACE panel circuit breaker to ON. See TM 11-7010-256-12&P. 4. Measure resistance between terminals (4) of circuit breaker CB16 (5). 5. Does multimeter read 0 ohms? BYN 1. Replace circuit breaker CB16 (WP 0730 00). 2. Verify no faults found. B2Y 1. Raise faceplate and secure to power control enclosure with ten new lockwashers and screws. 2. Go to Power Control Enclosure DC Input/Output Inoperative (WP 0071 00). 0073 00-4