TM 9-2350-261-20-1 NO DC POWER FROM TENT INTERFACE PANEL A5 — Continued 0073 00 Y 1. Turn MASTER SWITCH to OFF (see your -10). 2. Remove cable W32 plug P6 (1) from TENT INTERFACE panel jack J7 (2). 3. Measure resistance between pin A on plug P6 (1) and pin A on plug P16 (3) of cable W32. 3. Measure resistance between pin B on plug P6 (1) and pin B on plug P16 (3) of cable W32. 4. Does multimeter read 0 ohms for each set of measurements? YN 1. Replace cable W32 (WP 0749 00). 2. Verify no faults found. 2Y 1. Faulty tent interface panel. Beyond unit maintenance repair. 2. Notify supervisor. 0073 00-3