TM-9-2350-261-20-1 Unit Maintenance Manual Volume 1 M113A2 M577A2 M1064 M1068 M1059 M901A1 Download
Page 408 of 1236
TM 9-2350-261-20-1 NO AC POWER FROM TENT INTERFACE PANEL A5 — Continued 0072 00 T 1. Remove cable W32 plug P15 (1) from power control enclosure jack J32 (2). 2. Apply AC power to SICPS system. See TM 11-7010-256-12&P. 3. Measure voltage between socket A and socket B of jack J32 (2) and then between socket A and socket C. 4. Does multimeter read 110 volts AC or more for each measurement? TN GO TO BY (PAGE 0072 00-4) 0072 00-2