TM 9-2350-261-20-1 POWER CONTROL ENCLOSURE A1 DC INPUT/OUTPUT INOPERATIVE (M1068 ONLY) — Continued 0071 00 D4Y 1. Remove cable W38 plug P7 (1) from power control enclosure jack J28 (2). 2. Measure resistance between center of plugs P7 (1) and P6 (3) of cable W38. 3. Does multimeter read 0 ohms? D4YN 1. Replace cable W38 (WP 0751 00). 2. Verify no faults found. 0071 00-14 D5Y 1. Install cable W38 plug P7 (1) on power control enclosure jack J28 (2). 2. Install cable W38 plug P6 (3) on cable W29 plug P2 (4). 3. Install cable W29 plug P1 (5) and circuit 415 plug P1 (6) on adapter T2 (7). 4. Verify no faults found.