TM-9-2350-261-20-1 Unit Maintenance Manual Volume 1 M113A2 M577A2 M1064 M1068 M1059 M901A1 Download

Page 405 of 1236

TM 9-2350-261-20-1 POWER CONTROL ENCLOSURE A1 DC INPUT/OUTPUT INOPERATIVE (M1068 ONLY) — Continued 0071 00 D2Y 1. Set MASTER SWITCH to OFF (see your -10). 2. Remove cable W29 plug P1 (1) from adapter T2 plug P2 (2). 3. Measure resistance between adapter T2 plugs P2 (2) and P1 (3). 4. Does multimeter read 0 ohms? D2YN 1. Replace adapter T2 (WP 0751 00). 2. Verify no faults found. D3Y 1. Remove cable W29 plug P2 (1) from cable W38 plug P6 (2). 2. Measure resistance between plugs P2 (1) and P1 (3) of cable W29. 3. Does multimeter read 0 ohms? D3YN 1. Replace cable W29 (WP 0751 00). 2. Verify no faults found. 0071 00-13