TM-9-2350-261-20-1 Unit Maintenance Manual Volume 1 M113A2 M577A2 M1064 M1068 M1059 M901A1 Download
Page 394 of 1236
TM 9-2350-261-20-1 POWER CONTROL ENCLOSURE A1 DC INPUT/OUTPUT INOPERATIVE (M1068 ONLY) — Continued 0071 00 T 1. Loosen wing nut (1) and raise FAX hinged extension (2). 2. Loosen three wing nuts (3) and remove battery box cover (4). 3. Measure voltage between positive battery terminal (5) and ground. 4. Does multimeter read 22 volts DC or more? TN 1. Service carrier batteries (see your -10). 2. Verify no faults found. 0071 00-2