TM 9-2350-261-20-1 FRONT AND/OR REAR BILGE PUMP(S) AND/OR LIGHTS DO NOT OPERATE 0067 00 INITIAL SETUP: M a i n t e n a n c e L e v e l Unit T o o l s a n d S p e c i a l T o o l s Digital Multimeter (WP 0780 00, Item 43) General Mechanic’s Tool Kit (WP 0780 00, Item 29) P e r s o n n e l R e q u i r e d Unit Mechanic R e f e r e n c e s See your -10 E q u i p m e n t C o n d i t i o n Engine stopped (see your -10) Carrier blocked (see your -10) M ASTER SWITCH to OFF (see your -10) Power plant front access cover removed (front bilge pump) (WP 0429 00) Trim vane lowered and power plant front access door open (see your -10) Ramp lowered (rear bilge pump) (see your -10) Rear floor plate removed (rear bilge pump) (WP 0436 00) T 1. Turn MASTER SWITCH to ON (see your -10). 2. Turn BILGE PUMPS switch to ON (see your -10). 3. Do both bilge pump lights come on? TN GO TO BY (PAGE 0067 00-3) Y 1. Check to see if either bilge pump fails to come on. 2. Does either bilge pump fail to come on? YN GO TO CY (PAGE 0067 00-5) 0067 00-1