TM 9-2350-261-20-1 BATTERY/GENERATOR INDICATOR MALFUNCTIONS 0049 00 INITIAL SETUP: M a i n t e n a n c e L e v e l Unit T o o l s a n d S p e c i a l T o o l s Digital Multimeter (WP 0780 00, Item 43) General Mechanic’s Tool Kit (WP 0780 00, Item 29) P e r s o n n e l R e q u i r e d Unit Mechanic R e f e r e n c e s WP 0238 00 E q u i p m e n t C o n d i t i o n Engine stopped/shutdown (see your -10) Carrier blocked (see your -10) T 1. Remove instrument panel for access (WP 0238 00). 2. Remove circuit 27E plug (1) from battery generator indicator jack (2). 3. Remove circuit 10 plug (3) from instrument panel circuit breaker jack (4). 4. Measure resistance between circuit 27E plug (1) and circuit 10 plug (3). 5. Does multimeter read 0 ohms? TN 1. Repair master power harness circuit 27E (WP 0312 00). 2. Verify no faults found. Y 1. Replace BATTERY/GENERATOR indicator (WP 0240 00). 2. Verify no faults found. 00 4 9 00-1/2 blank