TM 9-2350-261-20-1 200 AMP OVER VOLTAGE TROUBLESHOOTING 0023 00 INITIAL SETUP: M a i n t e n a n c e L e v e l Unit T o o l s a n d S p e c i a l T o o l s Alternator Test Kit (WP 0780 00, Item 78) Electrical Connector Pliers (WP 0780 00, Item 44) General Mechanic’s Tool Kit (WP 0780 00, Item 29) Multimeter (WP 0780 00, Item 43) P e r s o n n e l R e q u i r e d Unit Mechanic R e f e r e n c e s See your -10 WP 0229 00 E q u i p m e n t C o n d i t i o n Engine stopped (see your -10) Carrier blocked (see your -10) T 1. Turn MASTER SWITCH to ON (see your -10). 2. Measure battery voltage by placing red lead (1) in positive socket of NATO plug (2) on auxiliary power (slave) receptacle (3). Touch black negative lead (4) to outside of NATO plug on receptacle. NOTE On carriers that have standard auxiliary power receptacles, touch red lead to positive and black lead to negative sockets in the receptacle. 3. Adjust voltage regulator (200 amp) to lowest setting (WP 0229 00). 4. Start engine and accelerate. 5. Does voltage climb to 32 to 34 volts and suddenly drop to battery voltage? TN GO TO BY (PAGE 0023 00-3) 0023 00-1