TM-9-2350-261-20-1 Unit Maintenance Manual Volume 1 M113A2 M577A2 M1064 M1068 M1059 M901A1 Download
Page 196 of 1236
TM 9-2350-261-20-1 200 AMP FULL FIELD CHARGE TROUBLESHOOTING — Continued 0022 00 2Y 1. Install cover and six screws on voltage regulator. 2. Connect alternator test kit (WP 0019 00). 3. Check capacitors from field to ground (test harness lead 2 to ground) with multimeter. 4. Does multimeter read between 100,000 ohms and infinity? 2YN 1. Replace generator (WP 0228 00). 2. Repeat charging system operational check (WP 0020 00). 3Y 1. Check capacitors from field to positive (test harness lead 3 to 4) with multimeter. 2. Does multimeter read between 100,000 ohms and infinity? 3YN 1. Replace generator (WP 0228 00). 2. Repeat charging system operational check (WP 0020 00). 4Y 1. Remove alternator test kit (WP 0019 00). 2. Replace voltage regulator (WP 0230 00). 3. Repeat charging system operational check (WP 0020 00). 0022 00-2