TM-9-2350-261-20-1 Unit Maintenance Manual Volume 1 M113A2 M577A2 M1064 M1068 M1059 M901A1 Download
Page 154 of 1236
TM 9-2350-261-20-1 ENGINE RUNS ROUGH, STALLS, OR DOES NOT PUT OUT FULL POWER — Continued 0013 00 Y Fuel flowing over a metal surface causes static electricity. This will cause a spark unless the surface is grounded. Loose clothing is dangerous around moving belts and pulleys. You could get badly hurt if your clothes get caught in moving parts. 1. Insert hose into metal container (1) with at least 1 gallon (4 liter) capacity. 2. Make sure container (1) is making metal-to-metal contact with carrier floor so there is a good ground. 3. Start engine (see your -10). Run engine at 1200 RPM for 1 minute. Hold end of fuel return hose in fuel. 4. Install rear half of quick disconnect on hose. 5. Place fuel return hose inside power plant compartment and connect hose to return line. Make sure quick disconnect snaps firmly in place. 6. Did fuel flow at least 1/2 gallon (2 liter) per minute? YN GO TO BY (PAGE 0013 00-7) 0013 00-2 WARNING WARNING