TM-9-2350-261-20-1 Unit Maintenance Manual Volume 1 M113A2 M577A2 M1064 M1068 M1059 M901A1 Download
Page 153 of 1236
TM 9-2350-261-20-1 ENGINE RUNS ROUGH, STALLS, OR DOES NOT PUT OUT FULL POWER 0013 00 INITIAL SETUP: M a i n t e n a n c e L e v e l Unit T o o l s a n d S p e c i a l T o o l s General Mechanic’s Tool Kit (WP 0780 00, Item 29) M a t e r i a l s / P a r t s Wiping rag (WP 0782 00, Item 76) Suitable container P e r s o n n e l R e q u i r e d Unit Mechanic Helper (H) R e f e r e n c e s See your -10 E q u i p m e n t C o n d i t i o n Engine stopped/shutdown (see your -10) Carrier blocked (see your -10) Air cleaner element cleaned (see your -10) Primary and secondary fuel filters serviced (see your -10) Trim vane lowered (see your -10) Power plant access door open (see your -10) Power plant rear access panels removed (see your -10) Rear compartment floor plates removed (WP 0436 00, WP 0437 00, WP 0438 00, WP 0440 00, or WP 0441 00) T C A U T I O N Keep return hose clear of generator drive belts. 1. Ensure manual shutoff valve is open (see your -10). 2. Push forward on quick disconnect coupling (1) to disconnect return hose (2) from fuel return line (3). 3. Pull return hose (2) with quick disconnect coupling (1) out of power plant compartment. Remove half of quick disconnect coupling (1) from return hose (2), and retain. 0013 00-1