TM 9-2350-261-20-1 ENGINE CRANKS BUT WILL NOT START BELOW 40 (AIR BOX HEATER IS USED) — Continued 0012 00 Y High voltage. Keep hands clear. 1. Release air box heater switch. 2. Turn MASTER SWITCH to OFF (see your -10). 3. Install air pump to air box heater hose onto air box heater (WP 0177 00 and WP 0183 00). 4. Remove air box igniter high voltage wire (1) and igniter (2). 5. Install high voltage wire (1) on igniter (2). 6. Ground touch hex portion of igniter (2) on idler pulley pivot. 7. Turn MASTER SWITCH to ON (see your -10). 8. Turn air box heater switch to ON (see your -10). 9. Does igniter produce a spark? YN GO TO CY (PAGE 0012 00-7) 0012 00-2 WARNING