TM-9-2350-261-20-1 Unit Maintenance Manual Volume 1 M113A2 M577A2 M1064 M1068 M1059 M901A1 Download

Page 123 of 1236

TM 9-2350-261-20-1 ENGINE DOES NOT CRANK 0009 00 INITIAL SETUP: M a i n t e n a n c e L e v e l Unit T o o l s a n d S p e c i a l T o o l s Digital Multimeter (WP 0780 00, Item 43) General Mechanic’s Tool Kit (WP 0780 00, Item 29) Socket Wrench Set (WP 0780 00, Item 96) P e r s o n n e l R e q u i r e d Unit Mechanic Helper (H) R e f e r e n c e s See your -10 E q u i p m e n t C o n d i t i o n Engine stopped/shutdown (see your -10) Carrier blocked (see your -10) Trim vane lowered (see your -10) Power plant access door open (see your -10) Driver’s power plant access panel removed (see your -10) T 1. Turn MASTER SWITCH to ON (see your -10). 2. Remove cover (1) from auxiliary power receptacle (2). 3. Measure voltage between positive (+) terminal (3) and negative (-) terminal (4). 4. Does multimeter read more 17 volts? TN 1. Clean, inspect, and repair carrier batteries (WP 0302 00 and WP 0303 00). 2. Verify no faults found. 0009 00-1