TM 9-2350-261-20-1 ENGINE OVERHEATS — Continued 0007 00 7Y WARNING Hot coolant lines can burn you. Let power plant cool before you remove hose from auxiliary tank. 1. Loosen hose clamp (1) on hose (2) at auxiliary tank (3). 2. Remove hose (2) from auxiliary tank (3). 3. Allow coolant to drain from elbow (4) on auxiliary tank (3). Use clean suitable container to catch coolant. 4. Install pipe plug (5) in hose (2) using hose clamp (1). 5. Remove elbow (4) from auxiliary tank (3). 6. Install bushing (6) on auxiliary tank (3). 7. Install radiator pressure tester (7) to bushing (6). 8. Pump system no higher than 15 psi pressure. 9. Does auxiliary tank filler cap relieve between 13 and 15 psi pressure? 7YN 1. Replace auxiliary tank filler cap (WP 0206 00). 2. Verify no faults found. 0007 00-4