TM-9-2350-261-20-1 Unit Maintenance Manual Volume 1 M113A2 M577A2 M1064 M1068 M1059 M901A1 Download

Page 115 of 1236

TM 9-2350-261-20-1 ENGINE OVERHEATS 0007 00 INITIAL SETUP: M a i n t e n a n c e L e v e l Unit T o o l s a n d S p e c i a l T o o l s General Mechanic’s Tool Kit (WP 0780 00, Item 29) Radiator Testing Kit (WP 0780 00, Item 52) Tube-Pipe Fitting Kit (WP 0780 00, Item 24) M a t e r i a l s / P a r t s Suitable container P e r s o n n e l R e q u i r e d Unit Mechanic Helper (H) E q u i p m e n t C o n d i t i o n Engine stopped (see your -10) Carrier blocked (see your -10) Trim vane lowered (see your -10) Power plant front access door open (see your -10) Driver’s power plant access panels removed (see your -10) Power plant rear access panels removed (see your -10) T 1. Check to see if engine is boiling over. 2. Does engine boil over? TN 1. Verify proper operation of coolant TEMP indicator before continuing (WP 0050 00). 2. Verify no faults found. Y 1. Observe coolant TEMP indicator (see your -10). 2. Does coolant TEMP indicator indicate overheating? YN 1. Verify proper operation of coolant TEMP indicator before continuing (WP 0050 00). 2. Verify no faults found. 2Y 1. Inspect power plant front access door, driver’s access panel, rear access panel, and bottom access cover seals (see your -10). 2. Are all parts and seals in good condition? 2YN 1. Repair, replace and/or adjust faulty parts and/or seals as required (WP 0426 00, WP 0427 00, WP 0428 00, WP 0429 00, WP 0430 00, WP 0431 00, and WP 0434 00). 2. Verify no faults found. 0007 00-1