TM-9-2350-261-20-1 Unit Maintenance Manual Volume 1 M113A2 M577A2 M1064 M1068 M1059 M901A1 Download
Page 1127 of 1236
TM 9-2350-261-20-1 REPLACE EXHAUST PIPES — Continued 0189 00 FOLLOW-THROUGH STEPS 1. Install air cleaner housing and element (WP 0185 00). WARNING Loose clothing is dangerous around moving belts and pulleys. You could get badly hurt if your clothes get caught in moving parts. 2. Start engine (see your -10). Check for leaks. 3. Engine stopped/shutdown (see your -10). 4. Close power plant front access door (see your -10). 5. Raise trim vane (see your -10). END OF TASK 0189 00-3/4 blank