TM-9-2350-261-20-1 Unit Maintenance Manual Volume 1 M113A2 M577A2 M1064 M1068 M1059 M901A1 Download

Page 1115 of 1236

TM 9-2350-261-20-1 REPLACE AIR CLEANER RESTRICTION INDICATOR AND HOSE — Continued 0186 00 WARNING Loose clothing is dangerous around moving belts and pulleys. You could get badly hurt if your clothes get caught in moving parts. 9. Start engine and set at 800 RPM (see your -10). 10. Block air cleaner outlet opening with a piece of cardboard. Check window in indicator. It should be red. 11. Turn engine off and remove cardboard. Indicator should remain red. 12. Press reset button on indicator. Window should turn green. 13. If indicator does not operate properly, replace it. FOLLOW-THROUGH STEPS 1. Engine stopped/shutdown (see your -10). 2. Install air cleaner outlet hose (WP 0183 00). 3. Close power plant front access door (see your -10). 4. Raise trim vane (see your -10). END OF TASK 0186 00-3/4 blank