TM 9-2350-261-20-1 REPLACE AIR CLEANER RESTRICTION INDICATOR AND HOSE — Continued 0186 00 INSTALLATION 1. Secure indicator (1) to bulkhead with two screws (2), washers (3), and new locknuts (4). WARNING Adhesive, primer, sealant compounds, and isopropyl alcohol are toxic and flammable. These compounds are toxic to eyes, skin, and respiratory tract. Continued exposure can make you dizzy and irritate your eyes and throat. Always use in well ventilated areas, away from heat, sparks, and flames. Do not breathe fumes. Do not allow into contact with skin and eyes. Use goggles or face shield and protective gloves. 2. Apply a thin coat of sealing compound to threads of adapter (5). 3. Install adapter (5) in indicator (1). 4. Connect indicator hose (6) to adapter (5). 5. Install air cleaner cover (WP 0184 00). 6. Install air cleaner housing and element (WP 0185 00). 7. Install air cleaner inlet hose (WP 0183 00). 8. Install driver’s power plant access panel (WP 0430 00). 0186 00-2