TM-9-2350-261-20-1 Unit Maintenance Manual Volume 1 M113A2 M577A2 M1064 M1068 M1059 M901A1 Download

Page 1094 of 1236

TM 9-2350-261-20-1 REPLACE AIR BOX HEATER — Continued 0180 00 INSTALLATION WARNING Adhesive, primer, sealant compounds, and isopropyl alcohol are toxic and flammable. These compounds are toxic to eyes, skin, and respiratory tract. Continued exposure can make you dizzy and irritate your eyes and throat. Always use in well ventilated areas, away from heat, sparks, and flames. Do not breathe fumes. Do not allow into contact with skin and eyes. Use goggles or face shield and protective gloves. 1. Apply sealing compound to cleaned external threads of fittings. 2. Install spray nozzle (1), elbow (2), and adapter (3) on air box heater body (4). 3. Place new gasket (5), new packing (6), and heater body (4) on engine. 4. Install heater body (4) on engine and attach three ground leads (7) to heater body. Secure with three washers (8) and screws (9). 5. Install elbow (10) in adapter (3). 6. Connect air hose (11) to elbow (10). 7. Connect lead (12) to igniter (13). FOLLOW-THROUGH STEPS 1. Install air box heater solenoid valve (WP 0179 00). 2. Connect battery ground lead (WP 0294 00). 3. Close power plant front access door and raise trim vane (see your -10). END OF TASK 0180 00-2