TM 9-2350-261-20-1 REPLACE AIR BOX HEATER AIR PUMP — Continued 0177 00 INSTALLATION WARNING Adhesive, primer, sealant compounds, and isopropyl alcohol are toxic and flammable. These compounds are toxic to eyes, skin, and respiratory tract. Continued exposure can make you dizzy and irritate your eyes and throat. Always use in well ventilated areas, away from heat, sparks, and flames. Do not breathe fumes. Do not allow into contact with skin and eyes. Use goggles or face shield and protective gloves. 1. Apply sealing compound to cleaned external threads of fittings. 2. Install elbows (7) and (9) in air pump (5). 3. Install air pump (5) and pad on mount (13). Secure with retainer (12), washer (11), and screw (10). 4. Install adapters (6) and (8) on elbows (7) and (9). 5. Secure leads (3) and (4) to air pump (5) with two washers (2) and nuts (1). FOLLOW-THROUGH STEPS 1. Connect battery ground lead (WP 0294 00). 2. Close power plant front access door and raise trim vane (see your -10). 3. Raise and lock ramp (see your -10). END OF TASK 0177 00-2