TM-9-2350-261-20-1 Unit Maintenance Manual Volume 1 M113A2 M577A2 M1064 M1068 M1059 M901A1 Download

Page 1009 of 1236

TM 9-2350-261-20-1 REPLACE FUEL RETURN HOSES, TUBES, AND FITTINGS (M577A2 AND M1068 ONLY) — Continued 0159 00 13. Install elbow (1) in filler neck (2). 14. Connect return tube (3) to elbow (1). 15. Connect return tube (3) to nipple (4) or tee (9) (M1068 Only). 16. Install return tube (3) on four weldnuts (5). Secure with four clamps (6), new lockwashers (7), and screws (8). FOLLOW-THROUGH STEPS 1. Install muffler (WP 0191 00). 2. Install personnel heater (WP 0620 00). 3. Install generator (WP 0227 00 or WP 0228 00). NOTE Electronic equipment heater is not installed if 5.0 KW APU is installed. 4. Install electronic equipment heater (WP 0633 00). 5. Connect battery ground lead (WP 0294 00). 6. Start engine (see your -10). Check return hoses for leaks. 7. Install map board (see your -10). 8. Install power plant rear access panel (WP 0433 00). 9. Raise and lock ramp (see your -10). 10. Engine stopped/shutdown (see your -10). END OF TASK 0159 00-7/8 blank