TM 9-2350-261-10 MAINTENANCE OF AIR CLEANER 0089 00 THIS WORK PACKAGE COVERS: Removal (page 0089 00-1). Cleaning (page 0089 00-2). Installation (page 0089 00-3). INITIAL SETUP: M a i n t e n a n c e L e v e l Unit P e r s o n n e l R e q u i r e d Driver R e f e r e n c e s DA Form 2404 WP 0014 00 WP 0047 00 E q u i p m e n t C o n d i t i o n Engine stopped (WP 0029 00) REMOVAL WARNING Failure to decontaminate and wear protective clothing after NBC attack could result in serious health hazards to personnel. Do not service air cleaner or vent system after NBC attack until carrier has been decontaminated. If NBC exposure is suspected, all air filter medial should be handled by personnel wearing protective equipment. Consult your unit NBC officer or NBC NCO for appropriate handling or disposal instructions. Unlatched hatch covers can swing and injure personnel. Make sure hatches are latched open or closed. C A U T I O N Operating carrier with air cleaner missing or damaged can cause extensive engine damage. Do not operate carrier if air cleaner element is missing or door or gasket is missing or damaged. NOTE You will have one of two air cleaner configurations. Body and elements are not interchangeable except as sets. 1. Lower trim vane (WP 0047 00). 2. Open power plant access door (WP 0014 00). 0089 00-1