TM 9-2350-261-10 PREVENTIVE MAINTENANCE CHECKS AND SERVICES — Continued 0075 00 ITEM NO. INTERVAL MAN- HOUR ITEM TO BE CHECKED OR SERVICED CREWMEMBER PROCEDURE EQUIPMENT NOT READY/ AVAILABLE IF: e. Check strainer element and clean if required. f. Check fuel can lids for leaks. Fuel cans cannot be secured to carrier. g. Check serviceability of webbing straps. h. Check all fuel, air, and fog oil hoses, electric cable assembly connectors, mount bolts, and clamps. Ensure they are not loose, damaged, twisted, torn, or leaking. Any leak of fuel, Class III oil, or air from any component of smoke generator system, or any electric wire damaged. i. Check for security of fuel cans to carrier. j. Drain waste oil from drip pan by removing and reinstalling plug. 0075 00-96