TM-9-2350-261-10 Operator Manual M113A2 M577A2 M1064 M1068 M1059 M901A1 Download
Page 500 of 764
TM 9-2350-261-10 PREVENTIVE MAINTENANCE CHECKS AND SERVICES — Continued 0075 00 Table 5. Preventive Maintenance Checks and Services for Model M113A2 FOV, After ITEM NO. INTERVAL MAN- HOUR ITEM TO BE CHECKED OR SERVICED CREWMEMBER PROCEDURE EQUIPMENT NOT READY/ AVAILABLE IF: 36 After Neutral Start Switch DRIVER NOTE “After” PREVENTIVE MAINTENANCE begins the moment the carrier engine shuts off after mission mode is completed. a. Check for proper operation of neutral start switch. Engine should only start with range selector in N range. Switch missing. Engine can be started in any forward or reverse range. b. Check range selector mounting screws. If screws are loose or missing, report it to unit maintenance. Mounting screws loose or missing. 37 After Engine Shutdown DRIVER WARNING Hot parts can burn you. Let hot parts cool before you start work. a. Stop engine (WP 0029 00). Engine won’t shut down. b. Check engine for proper shutdown. 1) Pull out hand throttle and run engine at 800 to 1000 RPM until normal idle temperature of 160 to 185 F (71 to 85 C) is reached as indicated by temperature gauge. 0075 00-52 º º º º