TM 9-2350-261-10 PREVENTIVE MAINTENANCE CHECKS AND SERVICES — Continued 0075 00 ITEM NO. INTERVAL MAN- HOUR ITEM TO BE CHECKED OR SERVICED CREWMEMBER PROCEDURE EQUIPMENT NOT READY/ AVAILABLE IF: 28 During Personnel Heater (Electronic Equipment Heater M577A2) DRIVER WARNING Do not operate personnel heater if any fuel leak is found in heater or in fuel lines. a. Check operation of electronic equipment heater. b. Check exhaust and intake ports for blockage. c. Check air outlet elbow for blockage. d. Check for leaks in fuel lines. Any Class III fuel leaks. 0075 00-45