TM-9-2350-261-10 Operator Manual M113A2 M577A2 M1064 M1068 M1059 M901A1 Download

Page 474 of 764

TM 9-2350-261-10 PREVENTIVE MAINTENANCE CHECKS AND SERVICES — Continued 0075 00 ITEM NO. INTERVAL MAN- HOUR ITEM TO BE CHECKED OR SERVICED CREWMEMBER PROCEDURE EQUIPMENT NOT READY/ AVAILABLE IF: NOTE On all carriers except M1068, portable fire extinguisher is located against curbside rear plate. On M1068, portable fire extinguisher is located against curbside wall next to the map board. NOTE Manually lower ramp before proceeding with PMCS. a. Check portable fire extinguisher control seal. Make sure seal or locking wire is not broken. Report broken seal to unit maintenance. Fire extinguisher missing. Seal or lockwire missing or broken. b. Check fire extinguisher for security of mounting hardware and missing hardware. c. Check for full charge. Pressure gauge indicates discharge or seal is broken. Extinguisher feels light or seal is broken, if no gauge. 0075 00-26