TM 9-2350-261-10 TROUBLESHOOTING TABLE — Continued 0074 00 INITIAL SETUP: M a i n t e n a n c e L e v e l Operator BILGE PUMPS MALFUNCTION TEST OR INSPECTION CORRECTIVE ACTION 1. BILGE PUMPS DO NOT OPERATE WITH BILGE PUMPS SWITCH ON. 1. Check to see if MASTER SWITCH is OFF. Turn MASTER SWITCH to ON (WP 0026 00). 2. Check to see if bilge pump strainers or outlets are clogged. Clean bilge pump strainers or outlets (WP 0086 00). 3. Check to see if bilge pump vents are blocked. Clean bilge pump vents (WP 0086 00). If you cannot get to the bilge pump to clean it because of a load in the personnel compartment, cycle the BILGE PUMP switch ON and OFF (WP 0086 00) a few times. That will usually start the pump. 0074 00-17/18 blank