TM-9-2350-261-10 Operator Manual M113A2 M577A2 M1064 M1068 M1059 M901A1 Download
Page 417 of 764
TM 9-2350-261-10 TROUBLESHOOTING TABLE 0074 00 INITIAL SETUP: M a i n t e n a n c e L e v e l Operator ENGINE MALFUNCTION TEST OR INSPECTION CORRECTIVE ACTION 1. ENGINE DOES NOT CRANK WHEN YOU PRESS START SWITCH. 1. Check to see if MASTER SWITCH is OFF. Turn MASTER SWITCH to ON (WP 0026 00). 2. Check to see if range selector controller is in N position. Place range selector in N position (WP 0026 00). 3. Check to see if batteries are in good condition. Troubleshoot electrical system (page 0074 00-15). 2. ENGINE CRANKS BUT DOES NOT START. 1. Check to see if fuel cutoff control is pulled out. Push fuel cutoff control in (WP 0026 00). 2. Check to see if there is enough fuel in fuel tanks. Refuel carrier; M113A2, M1064, and M1059 (WP 0030 00), M577A2 and M1068 (WP 0031 00). 3. Check to see if fuel tank manual shutoff valve is closed. Open fuel tank manual shutoff valve (WP 0004 00). 4. If temperature is colder than +40 F (+4 C), check to see if AIR BOX HEATER switch is ON. Use air box heater (WP 0026 00). 5. Check to see if there is water in the fuel. Drain primary and secondary fuel filters (WP 0090 00). 6. Check to see if engine is getting enough air. Check air cleaner restriction indicator (WP 0004 00). If indicator shows only red in the window, notify unit maintenance. Clear intake grill of any debris. If engine still does not start, notify unit maintenance. 3. ENGINE CRANKS BUT DOES NOT START WHEN THE TEMPERATURE IS BELOW +40 F (+4 C) AND AIR BOX HEATER IS USED. 1. Have unit maintenance check to see if air box heater system is operating properly. 2. Have unit maintenance check to see if air box heater fuel and air lines and electrical connections are tight. Tighten any loose connections. 0074 00-1 º º º º