TM-9-2350-261-10 Operator Manual M113A2 M577A2 M1064 M1068 M1059 M901A1 Download

Page 416 of 764

TM 9-2350-261-10 TROUBLESHOOTING SYMPTOM INDEX — Continued 0073 00 MORTAR CARRIER (M1064) BATTERY DRAWER DOES NOT STAY CLOSED .............................................................................................0074 00-27 BATTERY DRAWER DOES NOT OPEN OR CLOSE FREELY ........................................................................0074 00-27 MORTAR HATCH COVERS DO NOT STAY LOCKED IN CLOSED POSITION ............................................................................................................................................................0074 00-27 MORTAR HATCH COVERS DO NOT STAY LOCKED IN OPEN POSITION ............................................................................................................................................................0074 00-27 NBC KIT INSUFFICIENT AIR FLOW AT ALL STATIONS ...............................................................................................0074 00-23 AIR FLOW TOO HIGH AT ALL STATIONS .......................................................................................................0074 00-23 GAS PARTICULATE FILTER WILL NOT OPERATE WHEN SWITCH IS IN ON POSITION ................................................................................................................................................0074 00-23 PERSONNEL HEATER HEATER DOES NOT START WITH RUN-OFF-START SWITCH HELD IN START POSITION. HEATER MOTOR RUNS .............................................................................................0074 00-19 HEATER DOES NOT START WITH RUN-OFF-START SWITCH HELD IN START POSITION. HEATER MOTOR DOES NOT RUN ...........................................................................0074 00-19 HEATER OVERHEATS AND STOPS ..................................................................................................................0074 00-19 HEATER OVERHEATS AND DOES NOT STOP ................................................................................................0074 00-19 HEATER DOES NOT PUT OUT ENOUGH HEAT .............................................................................................0074 00-19 SMOKE GENERATOR (M1059) SMOKE GENERATOR SYSTEM ....................................................................................................SEE TM 3-1040-283-10 TRACKS AND SUSPENSION CARRIER PULLS TO ONE SIDE ........................................................................................................................0074 00-13 CARRIER THROWS TRACK ...............................................................................................................................0074 00-13 TOO MUCH NOISE IN TRACK OR SUSPENSION ...........................................................................................0074 00-13 CARRIER RIDES TOO HARD .............................................................................................................................0074 00-13 TRANSFER GEARCASE TRANSFER GEARCASE RUNS HOT OR NOISY ...............................................................................................0074 00-9 NO POWER FLOWS THROUGH THE TRANSFER GEARCASE WHEN THE ENGINE IS RUNNING ................................................................................................................................0074 00-9 TRANSMISSION TRANSMISSION DOES NOT DRIVE IN ANY RANGE .....................................................................................0074 00-5 TRANS OIL HI TEMP WARNING LIGHT COMES ON ......................................................................................0074 00-5 120–MM MORTAR AND TURNTABLE 120–MM MORTAR............................................................................................................................SEE TM 9-1015-250-10 5.0 KW AUXILIARY POWER UNIT (M577A2 AND M1068) 5.0 KW AUXILIARY POWER UNIT (M577A2 AND M1068) .................................................SEE TM 9-6115-664-13&P 0073 00-2