TM-9-2350-261-10 Operator Manual M113A2 M577A2 M1064 M1068 M1059 M901A1 Download
Page 397 of 764
TM 9-2350-261-10 OPERATE NBC KIT — Continued 0068 00 2. Turn AIR PURIFIER SWITCH OFF. 3. Stow hoses connected to Y connectors out of the way. 4. Install spring clip over air intake openings on the air purifier. 5. Clean air purifier housing with a clean cloth as soon as possible after operation. TURN NBC KIT ON IN CARRIER WITHOUT LITTER KIT WARNING Breathing excessive carbon monoxide gas can kill you. Keep fresh air flow. NBC kit and M42 protective mask will not protect you from carbon monoxide gas nor provide oxygen. 1. All crew members must put on their M42 protective masks. Adjust facepieces. 0068 00-3