TM-9-2350-261-10 Operator Manual M113A2 M577A2 M1064 M1068 M1059 M901A1 Download
Page 395 of 764
TM 9-2350-261-10 OPERATE NBC KIT 0068 00 THIS WORK PACKAGE COVERS: Turn NBC Kit On In Ambulance With Litter Kit (page 0068 00-1). Turn NBC Kit Off In Ambulance With Litter Kit (page 0068 00-2). Turn NBC Kit On In Carrier Without Litter Kit (page 0068 00-3). Turn NBC Kit Off In Carrier Without Litter Kit (page 0068 00-5). INITIAL SETUP: M a i n t e n a n c e L e v e l Operator P e r s o n n e l R e q u i r e d Soldier E q u i p m e n t C o n d i t i o n NBC kit installed TURN NBC KIT ON IN AMBULANCE WITH LITTER KIT WARNING Breathing excessive carbon monoxide gas can kill you. Keep fresh air flow. NBC kit and M42 protective mask will not protect you from carbon monoxide gas nor provide oxygen. 1. Remove spring clip from air intake openings on air purifier. NOTE Air purifier switches are located in various places, such as the instrument panel, transverse beam, near driver’s seat, and in the rear compartment. 2. Turn AIR PURIFIER SWITCH ON. 0068 00-1