TM-9-2350-261-10 Operator Manual M113A2 M577A2 M1064 M1068 M1059 M901A1 Download
Page 285 of 764
TM 9-2350-261-10 INSTALL/REMOVE M19 PERISCOPE 0042 00 THIS WORK PACKAGE COVERS: Installation (page 0042 00-1). Removal (page 0042 00-4). INITIAL SETUP: M a i n t e n a n c e L e v e l Operator P e r s o n n e l R e q u i r e d Driver E q u i p m e n t C o n d i t i o n Engine stopped (WP 0029 00) Driver’s hatch cover closed (WP 0007 00) Carrier blocked (WP 0050 00) INSTALLATION WARNING HIGH VOLTAGE IN THE M19 periscope can cause serious injury or death. To avoid accidents: ALWAYS connect power cable to periscope BEFORE turning MASTER SWITCH and I.R. power switch to ON. Always wait at least 2 minutes BEFORE you disconnect the power cable from the periscope when turning I.R. POWER switch and MASTER SWITCH OFF. NEVER disconnect the power cable from the periscope until the image disappears from the periscope screen. NEVER touch the end of the cable. Voltage could exceed 16,000 volts. 1. Squeeze latches and push up on plug assembly to release plug assembly from quick release. Tilt plug assembly to remove through opening in quick release. 0042 00-1