TM-9-2350-261-10 Operator Manual M113A2 M577A2 M1064 M1068 M1059 M901A1 Download
Page 269 of 764
TM 9-2350-261-10 OPERATE ELECTRONIC EQUIPMENT HEATER — Continued 0037 00 NOTE On the majority of heater control boxes, the control light comes on dimmed during the start cycle of the heater. When heater starts the light goes to full brightness. 3. Hold RUN-OFF-START switch to START until indicator light comes on. Then move switch to RUN, without stopping in OFF position. 4. Select high or low heat with HI-LO switch. Heater will always start on low heat no matter where switch is set. It will go to high after it starts if switch is at HI. 5. If heater doesn’t start, try again. If it doesn’t start in three tries, troubleshoot heater (WP 0074 00). TURN HEATER OFF 1. Move RUN-OFF-START switch to OFF. Heater will continue to operate for a few minutes until fuel is burned. Then it will shut itself off. END OF TASK 0037 00-3/4 blank