TM-9-2350-261-10 Operator Manual M113A2 M577A2 M1064 M1068 M1059 M901A1 Download

Page 266 of 764

TM 9-2350-261-10 OPERATE PERSONNEL HEATER — Continued 0036 00 NOTE Personnel heater always starts at low heat. It changes to high heat if HI-LO switch is set at HI. 9. Move HI-LO switch to HI or LO. NOTE Steps 10 - 11 apply to heater Model A20 P/N 5000-310178 only. 10. Move the RUN-OFF-START switch momentarily to START for at least four (4) seconds, and then move the switch to RUN. The heater will now run automatically and does not require any further actions by the operator. 11. Control box warning indicator light. If the control box lamp begins to flash the heater is signaling that an abnormal condition is present. See TM 9-2540-207-14&P for diagnostic display codes and corrective action. TURN PERSONNEL HEATER OFF NOTE If you operate heater for an extended time, start engine to keep batteries charged (WP 0026 00). NOTE When personnel heater is turned off, blower will run until personnel heater cools off. HEATER light will go off when personnel heater cools off. Driver should stay in carrier until blower stops. 1. Move RUN-OFF-START switch to OFF. 2. Let personnel heater purge itself. END OF TASK 0036 00-4