TM-9-2350-261-10 Operator Manual M113A2 M577A2 M1064 M1068 M1059 M901A1 Download

Page 265 of 764

TM 9-2350-261-10 OPERATE PERSONNEL HEATER — Continued 0036 00 4. Make sure HI-LO switch is set to LO before starting. NOTE On the majority of the heater control boxes, the control light comes on dimmed during start cycle of the heater. When heater starts the light goes to full brightness. 5. Move RUN-OFF-START switch to START for 2 minutes. If HEATER light does not come on, move RUN-OFF-START switch to OFF for 10 seconds. Move RUN-OFF-START switch to START for 1 minute. If HEATER light does notcome on, move RUN-OFF-START switch to OFF for 10 seconds. Move RUN-OFF-START switch to START for 1 minute. If heater fails to start after third try, troubleshoot heater (WP 0074 00). 6. Move RUN-OFF-START switch to RUN as soon as HEATER light comes on. Do not stop in OFF position. 7. Move RUN-OFF-START switch to START for 4 minutes. If HEATER light does not come on, move RUN-OFF-START switch to OFF. Wait at least 15 minutes. Move RUN-OFF-START switch to START for 4 minutes. If heater fails to start after second try, troubleshoot heater (WP 0074 00). 8. Move RUN-OFF-START switch to RUN as soon as HEATER light comes on. Do not stop in OFF position. 0036 00-3